Project: Red Bull Track Line Modification and Salvage ( PQ4-230kV )

Customer: SaskPower

Project Status: Complete

Voltage: 230kV

Category: Transmission / Energized services

Allteck's job was to modify the existing PQ4 transmission line crossing to accommodate a new CP Rail spur line (Red Bull Track) currently under construction in the area. Included in the job was the relocation of an existing galvanized steel H-Frame structure type T73-001-VC-01-25m support height. The existing structure was to be removed and re-installed approximately 30m from existing location. The existing structure is direct embedded in steel casing.

Project: Transmission Tower Steel Upgrades and Damper Replacements

Customer: SaskPower

Project Status: In-Progress

Voltage: 230kV Double Circuit

Category: Transmission / Energized services

The scope of work includes the following items on existing galvanized steel transmission structures with energized double circuit 230kV transmission lines;
• Supply and installation of steel tower body upgrade kits
• Supply and installation of overhead shield wire arm (OHSW) upgrade kits and phase conductor arm upgrade kits
• Energized replacement of existing torsional conductor dampers with new Mosdorfer phase conductor dampers
• OHSW insulator removal and bonding of the OHSW to the tower structure and installation of OHSW Spiral Dampers

Project: Meikle Wind Energy 230kV Switchyard

Customer: SNC Lavalin

Project Status: Complete, In service

Voltage: 230kV

Category: Substations

Completion of a 10 month project consisting of 61 GE turbines which generate 180MW at full capacity.

Project: K1T 230kV Water Structure Replacements

Customer: SaskPower

Project Status: Complete

Voltage: 230kV

Category: Transmission / Energized services

Replace 10 existing Energized D17-1 230kV Gulfport Tangent Structures with new D17-1 230kV Gulfport Tangent Structures installed in screw pile foundations

The Challenges
Winter work in the Qu’Appelle Valley flood plain. Limited access requiring access matting and river crossings.

Specialized Work Methods
Robotic Arm’s and Barehand Work Procedures required

Project: Happy Valley T4 Terminal Station Upgrades

Customer: Nalcor

Project Status: In Progress

Voltage: 138/ 25kV

Category: Substations

Scope of work includes-
• Installation of reinforced concrete foundations
• Installation of conduit
• Assembly and installation of steel structures
• Installation of 138kV disconnect switch
• Installation of 138kV post insulators
• Installation of 138kV rigid bus
• Installation of 25kV post insulators
• Installation and testing of 25kV potential transformer
• Installation, testing and pre-commissioning of 25kV vacuum circuit breaker
• 25kV bus reconfiguration (Live Line work)
• Installation and testing of 25kV disconnect switch T4B14-1
• Removal and installation of equipment and structure grounding
• Installation of T4 protection panel and power and control cables
• Final grading and supply and placement of yard gravel

Project: Bottom Waters Distribution Upgrade

Customer: Nalcor

Project Status: In Progress

Voltage: 25kV

Category: Energized services

Replace Hendrix insulators on 176 existing three phase distribution structures with porcelain line post insulators, also replace deteriorated crossarms on poles where insulators are to be replaced.

Project: Acamac

Customer: Energie NB Power

Project Status: In Progress

Voltage: 138kV

Category: Transmission

Replace conductor on the 1km Acamac double circuit crossing on 138 kV lines 1147 & 1165 to increase thermal rating and increase overall capacity.
Project will be complete with one circuit de-energized at a time and the other circuit continuously in service.

Project: L11 Line Conversion Project

Customer: Nalcor

Project Status: In Progress

Voltage: 4kV to 25kV

Category: Distribution

This is a 4kV to 25kV conversion project which includes replacement of transformers, poles, insulators, conductor and associated hardware utilizing "Live Line" techniques and tension stringing methodology.

Project: Dismantle and Construct 69 kV Transmission Line 0039

Customer: Energie NB Power

Project Status: In Progress

Voltage: 69kV

Category: Energized services

Line 0039 existing structure #14 to #327 goes from Marysville area to Boiestown Area and line 0039X is the tap of line 0039 to Boiestown Substation existing structures #326A to 326H.
Distance of Re-Build is approximately 64 km and 317 structures of various types.
This project will be completed with Allteck's Robotic Arm on various off road track equipment as well as traditional rubber tired vehicles.

Project: Meikle Terminal

Customer: SNC Lavalin

Project Status: Complete

Voltage: 230kV

Category: Substations

Meikle Terminal is a 230kV Switchyard built to tie in the transmission line for Pattern Energy's Meikle Wind Energy Project 38 kilometers Southwest of Tumbler Ridge BC. Allteck performed the civil, electrical, steel erection, bus installation and line tie-in for the project.

Project: PE3 138kV Structure Replacements

Customer: SaskPower

Project Status: Completed 2015

Voltage: 138kV

Category: Transmission

Allteck completed the structure replacements for both energized and de-energized structures in Peebles, Saskatchewan

Project: Distribution line for Mine Decommissioning

Customer: Teck Metals – Pinchi Mine

Project Status: Completed 2010

Voltage: 25kV

Category: Distribution

25kV Distribution line for Mine Decommissioning

Project: Reactor and Arrestor install

Customer: Canfor Pulp

Project Status: Completed 2013

Voltage: 69kV

Category: Transmission

Allteck installed a reactor and arrestor in a substation for a TG Upgrade

Project: Underground cable repair

Customer: CN Rail

Project Status: Completed 2012

Voltage: 25kV

Category: Distribution

Allteck repaired 25kV Underground cables after River Bank Erosion occurred

Project: Construction of 69kV transmission line

Customer: BC Hydro

Project Status: In progress

Voltage: 69kV

Category: Transmission

Allteck is constructing a 69kV Transmission Line for relocation Highway 97

Project: Primary switch and underground installation

Customer: NADLEH WHUT’EN Administration Building

Project Status: In progress

Voltage: 25kV

Category: Distribution

Allteck installed primary switch and 25kV Underground to Padmount Transformer

Project: Install of recloser for distribution upgrade

Customer: Walter Energy - Willow Creek Mine

Project Status: Completed 2012

Voltage: N/A

Category: Distribution

Install recloser and associated equipment for Distribution upgrade

Project: Substation Maintenance

Customer: Canadian Natural Resources Limited

Project Status: Completed 2014

Voltage: 230kV

Category: Transmission

Allteck performed substation maintenance

Project: Construction of power line for substation upgrade

Customer: Dunkley Lumber

Project Status: Completed 2014

Voltage: 25kV - 69Kv

Category: Distribution

Allteck constructed 69kV AND 25kV Power line for a substation upgrade

Project: Install of 25kV line

Customer: Canadian Forest Products

Project Status: Completed 2015

Voltage: 25kV

Category: Distribution

Allteck installed 25kV Distribution power for a relocated sorter building

Project: Rerout 25kV of reclaimed power line

Customer: Imperial Metals - Huckleberry Mines

Project Status: Completed 2012

Voltage: 25kV

Category: Distribution

Allteck rerouted 25kV of reclaimed power line

Project: 25kV Distribution line construction

Customer: Thompson Creek Metals - Endako Mines

Project Status: Completed 2011-2013

Voltage: 25kV

Category: Distribution

25kV Distribution line for Denak Pit and 25kV Distribution line for seepage pond

Project: Hilltop substation relocation and installation

Customer: Thompson Creek Metals - Endako Mines

Project Status: Completed 2011-2013

Voltage: 25kV - 69Kv

Category: Substations

Hilltop 69kV Substation relocation, DNK 69kV Substation installation

Project: Amp replacement and disconnect switch

Customer: Pinnacle Pellet

Project Status: Completed 2014

Voltage: 138kV

Category: Transmission

Allteck replaced 1200amp 138kV Disconnect Switch

Project: install and maintenance for Canadian Forest Products

Customer: Canadian Forest Products

Project Status: Completed 2014

Voltage: 69kV

Category: Distribution

Allteck provided maintenance and installation of a 25kV Metering Kit

Project: New line construction for private line

Customer: Pacific BioEnergy

Project Status: Completed 2014

Voltage: 25kV

Category: Distribution

Allteck constructed a new 25kV power line from a privately owned 69kV substation to a pellet plant

Project: Switch install for Pulpmill substation

Customer: Canfor Pulp Ltd- Northwood Pulpmill

Project Status: Completed 2015

Voltage: 69kV

Category: Transmission

Allteck installed a new 69kV switch for a pulpmill substation

Project: Underground feeder cable install for pulpmill

Customer: Canfor Pulp Ltd- Northwood Pulpmill

Project Status: Completed 2013

Voltage: 25kV

Category: Distribution

Allteck installed 25kV of underground feeder cables and switch gear for a Prince George Sawmill

Project: Distribution line install for rebuilt sawmill

Customer: Babine Forest Products

Project Status: Completed 2013

Voltage: 25kV

Category: Distribution

Allteck installed 25kV Distribution line for a rebuilt sawmill which consisted of 8 spans, 6 reclosers and load break switches

Project: Telus Cell Site Install at Firth Lake

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 10 poles and a load break switch

Project: Telus Cell Site Install at Fraser Lake

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 3 poles and a load break switch

Project: Telus Cell Site Install at Salmon River

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 2 poles and a load break switch

Project: Telus Cell Site Install at Augustine Lake

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 12 poles and a load break switch

Project: Telus Cell Site Install at Summit Lake

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 3 poles and a load break switch

Project: Telus Cell Site Install at Dome Creek

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 4 poles and a load break switch

Project: Telus Cell Site install at Goat River

Customer: Telus

Project Status: Completed

Voltage: 14.4kV

Category: Distribution

This line was one of seven single phase 14.4kV power lines to Telus cell sites. This line consisted of 8 poles and a load break switch

Project: Switch Maintenance at Bedeque Substation

Customer: Maritime Electric

Project Status: In Progress

Voltage: 30-138kV

Category: Energized services

Allteck will be utilizing our category "A" Bare hand vehicle on our insulated scaffolding unit to perform switch maintenance on 30-138kV switches at this location

Project: Line T-21 Reinsulation project

Customer: Maritime Electric

Project Status: In Progress

Category: Energized services

Allteck is reinsulating 70 single pole structures and changing to an armless framing. The Linemaster Robotic arm will be used to complete this project

Project: Line T-10 Reinsulation project

Customer: Maritime Electric

Project Status: In Progress

Category: Energized services

Allteck is reinsulating 137 single pole structures and changing to an armless framing. We will also complete 2 structure replacements. The Linemaster Robotic Arm will be used to complete this project.

Project: Estevan East Substation

Customer: SaskPower

Project Status: Completed

Voltage: 138kV

Category: Energized services

Allteck installed seven 138kV structures and a 138kV switch, feeding into the new SaskPower substation. Barehand crews used specialized procedures to energize the new line and substation by installing in-line openers to isolate the circuit going in and out of the new station.

Project: Williams Lake 60kV Hwy Relocation

Customer: Arctic Arrow Powerline Group

Project Status: Ongoing

Voltage: Single & Double Circuit 60kV with 25kV underbuilt portions

Category: Transmission

This project consisted of the relocation of 60L308 and 60L309 for the new Hwy 97 Ministry of Transportation upgrades from Carson Road to Fox Mountain Road in Williams Lake as well as the relocation of 8 double circuit 60kV poles with 25kV underbuilt and 8 60kV poles, some with 25kV underbuilt.

Project: BC Hydro Maintenance

Customer: BC Hydro

Project Status: Completed

Voltage: 25kV

Category: Distribution

This Project consisted of the replacement of old porcelain cutouts and associated hardware. Aging porcelain cutouts are prone to failure and a replacement program was implemented to increase system reliability.

Project: TL201 Priority Sleeve Repair

Customer: Nalcor

Project Status: Completed

Voltage: 230kV

Category: Energized services

The project consisted of installing the ClampStar product in parallel with the existing sleeve on TL201 using Barehand techniques on a live 230kV system.

Project: North Saskatchewan Distribution Backlog

Customer: SaskPower

Project Status: Completed

Voltage: 5kV - 72kV

Category: Distribution

The purpose of this contract was to provide SaskPower with resources to carry out designated work associated with the construction and salvage of SaskPower’s overhead and underground electric distribution system within the contract area. Services included pole changes, maintenace, liveline work, and material hauling.

Project: Rural Rebuild and Salvage Program

Customer: SaskPower

Project Status: Completed

Voltage: 5kV - 72kV

Category: Distribution

The purpose of this contract was to provide SaskPower with resources to carry out designated work associated with the construction and salvage of SaskPower’s overhead and underground electric distribution system within the contract area. Services included pole changes, maintenace, liveline work, and material hauling.

Project: Weyburn, SK – West Area Backlog

Customer: SaskPower

Project Status: Completed

Voltage: 5kV - 72kV

Category: Distribution

The purpose of this contract was to provide SaskPower with resources to carry out designated work associated with the construction and salvage of SaskPower’s overhead and underground electric distribution system within the contract area. Services included pole changes, maintenace, liveline work, and material hauling.

Project: 138kV Energized Structure Replacement

Customer: Enmax

Project Status: Completed 2009

Voltage: 138kV

Category: Energized services

Enmax required that three 138kV double circuit structures be relocated and conductors had to be raised to enable construction of a Rapid Transit System.

Project: 230kV COB Insulator Replacements

Customer: BC Transmission Corp

Project Status: Completed 2004

Voltage: 230kV

Category: Energized services

energized replacement of defective Canadian Ohio Brass insulators

Project: Cranbrook 60kV Energized Rebuild and Reconductor

Customer: BC Transmission Corp

Project Status: Completed 2006

Voltage: 60kV

Category: Energized services

Replace 60kV structures with underbuild and reconductor without circuit outage in rural and urban environment

Project: 138kV Structure Replacements and OPGW Installation

Customer: City of Lethbridge

Project Status: Completed 2008

Voltage: 138kV

Category: Energized services

Energized replacement of 19 double circuit concrete structures with 22 double circuit wood structures and install fibre optic cable to substation.

Project: 500kV Liveline Insulator Washing Project

Customer: BC Hydro

Project Status: Completed 2004-2010

Voltage: 500kV

Category: Energized services

Ongoing annual project to clean 500kV insulator strings of contamination with circuits to remain energized

Project: Dokie 230kV Substation Energization and Cut-in

Customer: BC Hydro

Project Status: Completed 2010

Voltage: 230kV

Category: Energized services

Replace 6 tangent structures, install two 90 degree deadend structures, string 2km of static wire, covert single 230kV circuit into 2 distinct circuits and connected new Windfarm to BC Hydro system without an outage to only transmission circuit feeding pulp mill and Tumbler Ridge. This was the first time such an activity was successfully attempted and completed

Project: Wester Coal Substation Energization

Customer: Western Coal

Project Status: Completed 2011

Voltage: 230kV

Category: Energized services

Converted a tangent structure into 3 pole deadend tap structure and installed tap to energize the substation without an outage.

Project: 138kV Circuit Reconfiguration and Substation Cut-in

Customer: Artic Arrow Powerlines

Project Status: Completed 2011

Voltage: 138kV

Category: Energized services

Energized new substation and reconfigure transmission circuit's single tangent structure into two separate deadend structures without an outage.

Project: 240kV Structure Raise / Relocation

Customer: Alta Link

Project Status: Completed 2012

Voltage: 240kV

Category: Energized services

Double circuit 240kv lattice tower relocation to improve road clearance

Project: 138kV Double Circuit Structure Installation

Customer: Enmax

Project Status: Completed 2012

Voltage: 138kV

Category: Energized services

Install a 138kV steel pole for clearance for new construction

Project: 138kV Energized Structure Replacements

Customer: Enmax

Project Status: Completed 2009

Voltage: 138kV

Category: Energized services

Relocate three 138kV double circuit transmission structures energized for road relocation

Project: Interphase Spacer Installation

Customer: SNC Lavalin

Project Status: Complete

Voltage: 240kV

Category: Transmission

Install interphase spacers on a 240kV double circuit line de-energized

Project: Fibre Optic Line Installation

Customer: Northern BC Client

Project Status: Complete

Voltage: n/a

Category: Transmission

Install two fibre optic cables on existing double circuit transmission towers (one circuit hot)

Project: Fibre Regeneration Site Power Line

Customer: Valard Construction

Project Status: Complete

Voltage: 25kV

Category: Distribution

Construct new 21 pole 12kV power line from private substation to fibre optic generation site

Project: Nisga’a Fibre Installation

Customer: Nisga'a Lisims Government

Project Status: Completed

Voltage: N/A

Category: Distribution

Install fibre optic line from New Ayanish Substation to New Ayanish

Project: Moresby Lake Transmission Line Maintenance

Customer: Atlantic Power

Project Status: Ongoing

Voltage: 69kV

Category: Transmission

Pole Replacements and annual inspections

Project: Terrace Mountain Airport Beacon Powerline

Customer: Progressive Ventrues

Project Status: Completed

Voltage: 600kV

Category: Distribution

Construct new 16 pole powerline up Terrace Mountain to airport beacon tower

Project: Dasque Transmission Line

Customer: Veresen

Project Status: Completed

Voltage: 138kV

Category: Transmission

Construct new 23km 69kV Transmission Line

Project: BR11 North Battleford

Customer: SaskPower

Project Status: Completed 2012

Voltage: 138kV & 230kV

Category: Transmission / Emergency restoration

June 26, 2012 Saskatchewan was hit with multiple tornadoes across the province. Allteck crews were dispatched to the North Battleford area where 2 major transmission circuits were damaged and thousands of residential and industrial customers were without power.

Project: Kirby SAGD Interconnection Line Construction

Customer: SNC Lavalin

Project Status: Completed

Voltage: 138kV

Category: Transmission

Project: BC Hydro ROC – Smithers, Houston, Burns Lake, Vanderhoof and Fort St. James

Customer: BC Hydro

Project Status: Ongoing

Voltage: 25kV

Category: Distribution

The Regionally Optimized Contracts (ROC), or Regionally Optimized Distribution Line Construction Work program, are multi-year unit price contracts to provide distribution overhead and underground (4-69kV) and secondary service work within designated regions throughout the Province of British Columbia. Categories of work include planned, short cycle, and time sensitive (TSS) work. Areas included Smithers, Houston, Burns Lake, Vanderhoof and Fort St. James

Project: BC Hydro ROC – Prince George

Customer: BC Hydro

Project Status: Ongoing

Voltage: 25kV

Category: Distribution

The Regionally Optimized Contracts (ROC), or Regionally Optimized Distribution Line Construction Work program, are multi-year unit price contracts to provide distribution overhead and underground (4-69kV) and secondary service work within designated regions throughout the Province of British Columbia. Categories of work include planned, short cycle, and time sensitive (TSS) work. Area covered Prince George

Project: BC Hydro ROC – Terrace, Prince Rupert, Kitimat and Stewart

Customer: BC Hydro

Project Status: Ongoing

Voltage: 25kV

Category: Distribution

The Regionally Optimized Contracts (ROC), or Regionally Optimized Distribution Line Construction Work program, are multi-year unit price contracts to provide distribution overhead and underground (4-69kV) and secondary service work within designated regions throughout the Province of British Columbia. Categories of work include planned, short cycle, and time sensitive (TSS) work. Areas included, Terrace, Prince Rupert, Kitimat and Stewart

Project: BC Hydro ROC – Williams Lake and Quesnel

Customer: BC Hydro

Project Status: Ongoing

Voltage: 25kV

Category: Distribution

The Regionally Optimized Contracts (ROC), or Regionally Optimized Distribution Line Construction Work program, are multi-year unit price contracts to provide distribution overhead and underground (4-69kV) and secondary service work within designated regions throughout the Province of British Columbia. Categories of work include planned, short cycle, and time sensitive (TSS) work. Areas included Williams Lake and Quesnel

Project: BC Hydro ROC – Victoria and Eastern Gulf Islands

Customer: BC Hydro

Project Status: Ongoing

Voltage: 25kV

Category: Distribution

The Regionally Optimized Contracts (ROC), or Regionally Optimized Distribution Line Construction Work program, are multi-year unit price contracts to provide distribution overhead and underground (4-69kV) and secondary service work within designated regions throughout the Province of British Columbia. Categories of work include planned, short cycle, and time sensitive (TSS) work. Areas included Victoria and the Eastern Gulf Islands

Project: B3P Rafferty Dam Flood Channel Reinforcement

Customer: SaskPower

Project Status: Completed 2014

Voltage: 138kV

Category: Energized services

Relocations and or replacement of 7 structures, current structures were located in a flood channel and more robust structures with strong foundations for maximized reinforcement was required

Project: R7B Rafferty Dam Flood Channel Reinforcement 13/14

Customer: SaskPower

Project Status: Completed 2014

Voltage: 230kV

Category: Energized services

Relocations and or replacement and reinforcement of 6 structures. Current structures were located in a flood channel and more robust structures with strong foundations for maximized reinforcement was required.

Project: B1W Line Span Remediation

Customer: SaskPower

Project Status: Completed 2014

Voltage: 138kV

Category: Transmission

Relocation of existing 138kV structures required to meet adequate vertical clearance for navigable water under maximum thermal loading of conductor

Project: W1Y – East Capital Remediation

Customer: SaskPower

Project Status: Completed 2014

Voltage: 138kV

Category: Energized services

Structure replacements

Project: R2F Fleet Street Tap 230kV JS 4686-B

Customer: SaskPower

Project Status: Completed 2014

Voltage: 230kV

Category: Energized services

Removal of shield wire from one span in the existing R2F 230kV line tap, installation and stringing of 4.2km of T72 series H-frame construction

Project: P1HN/ P1HS

Customer: SaskPower

Project Status: Completed 2015

Voltage: 138kV

Category: Transmission

600 H-Frame structure change outs

Project: Saskatchewan energized insulator washing project

Customer: SaskPower

Project Status: Completed

Voltage: 138kV

Category: Energized services

Allteck cleaned energized structures around PCS Rocanville Potash Mine. Contaminated structures around mine causing outages.

Project: Churchill Falls Labrador, jumper removal

Customer: Nalcor Energy

Project Status: Completed

Voltage: 230kV

Category: Energized services

The project consisted of removing 3 jumpers from an energized 230kV switch in Nalcor's Churchill Falls Substation.

Project: Saskatchewan Energized, Estevan

Customer: SaskPower

Project Status: Completed

Voltage: 138kV

Category: Energized services

Allteck installed seven 138kV structures and a 138kV switch going to a SaskPower substation. Barehand crews then used specialized procedures to energize the new line and substation.

Project: 138kV Split Line Project – Civil, Electrical, P&C, and SCADA

Customer: SNC Lavalin

Project Status: Aug. 2013

Voltage: 138kV

Category: Substations

As part of the Red Deer Area Transmission Development (RATD) Project, the scope of work includes splitting of 138kV lines 768L/778L where the two lines are connected outside of two facilities viz. Gaetz 87S and North Red Deer 217S, extending 768L into Gaetz 87S and North Red Deer 217S, and installing breakers at the substation to accommodate the new line terminations. The existing telecommunication tower adjacent to the control building was moved to allow for the new line termination.

Project: Benalto 17S Transformer Addition

Customer: SNC Lavalin

Project Status: Feb. 2013

Voltage: 240kV

Category: Substations

Addtion of a second 240/138kV transformer and related 240kV and 138kV development, including the following:
- Steel structures and Bus-works.
- Installation and commisioning of one 120/160/200 MVA 240/138kV transformer with one motor operated disconnect.
- Connection of a transformer to 138kV Main Bus with a strain bus terminated on two 138kV A-frame structures.
- Installation of oil containment pad, one 240kV circuit breker and two 138kV circuit breakers.
- All P&C and SCADAworks completed.
- Testing and commissioning completed in preparation for energization.

Project: Kitimat LNG: JV 25kV Electrical Powerline Project

Customer: JGC Fluor

Project Status: ---

Voltage: 25kV

Category: Distribution

Scope of work: engineer, design, supply and install new bypass 25kV bypass over powerline to connect the early works camp and essential site loads.

Project: Oil Resevoir Top Up

Customer: Glencore Corp

Project Status: 2015

Voltage: 138kV

Category: Underground cable

Adjustment of level/pressure of oil in submarine cable system.

Project: Q3E 72kV Queen Elizabeth

Customer: SaskPower

Project Status: 2015

Voltage: 72kV

Category: Energized services

AG028 Q3E 72kV Structure Replacements - Replace, repair and inspection of multiple transmission structures on Q3E-Queen Elizabeth, Q3E-East, Q3E-Aspen Grove, Q3E-Elstow and Q3E-West transmission lines. Energized at 72kV.

Project: 138kV XLPE Cable Pull and Splice

Customer: Hooper Corporation

Project Status: Dec. 2014

Voltage: 138kV

Category: Underground cable

Long Lake Solar Project- South wire installation of XLPE 138kV cables, NKT terminations and test.

Project: Queensland 301S substation

Customer: Burns and McDonnell

Project Status: Mar. 6, 2015

Voltage: 138kV

Category: Substations

The Queensland 301S Substation was a greenfield site and only needed an outage to cut in the final lines into the substation and energize the equipment. The scope of work includes:
- One 138/6.9kV 20/26/33 MVA transformer unit .
- One 138kV live tank circuit breaker and the associated 138kV and 6.9kV equipment.
- Installation of a new control house.
- Furnish test plans, commissioning plans, and final documentation for energized and commissioning.

Project: 72kV Prysmian Terminations

Customer: Power System Asset Management Solutions

Project Status: 01/06/2014

Voltage: 72kV

Category: Underground cable

Installation of six 72kV Prysmian terminations

Project: 18#s Pfisterer Connex Size 4 – terminations

Customer: Power System Asset Management Solutions

Project Status: 01/06/2014

Voltage: 72kV

Category: Underground cable

Installation of Size 4 Pfisterer plug in terminations

Project: Line rehabilitation on 14-17 Lines – approx 17kms ea. With 110 structures p/line

Customer: FortisBC

Project Status: Oct. 2014

Voltage: 63kV

Category: Transmission

Line rehabilitation on 110 strucutres with 14-17 lines spanning 17kms each. The scope included:
- Three DDE 3 Pole Change
- Change H-frame on approx. 45 structures; majority performed energized
-Installation of two marker balls
- Miscellaneous work on over 100 structures

Project: 11 Line Rehabilitation Services

Customer: FortisBC

Project Status: Oct. 2015

Voltage: 138kV

Category: Transmission

Structure replacements and various structure rehabilitations spanning over 100 structures from the Kettle Valley Substation in Rock Creek, BC to A.S. Mawdsley Substation in Rossland, BC. The scope includes:
- 16 H-frame replacements; majority performed energized
- Two 3 Pole DDE Replacements
- Replace/Install 18 X-braces
- Miscellaneous work on over 100 structures

Project: 12S and 89S Hartland project by pass lines

Customer: SNC Lavalin

Project Status: 2014

Voltage: 240kV

Category: Transmission

Construct 240kV bypasses inside Ellerslie and Heartland Substations using 1033 ACSR for the purpose of energizing a new 500kV transmission line at 500kV until the transformer arrived.

Project: Blackspring Ridge Permanent Line Construction- near Vulcan, AB

Customer: SNC Lavalin

Project Status: 2013

Voltage: 240kV

Category: Transmission

55 Steel H-frame Structures direc tburied and with driven pipe foundations. 1033 ACSR single conductor with OHSW.

Project: Supply and Installation of the GIS Cable Plugs (Pfisterer) and Voltage Detectors

Customer: Black and McDonald

Project Status: 2014

Voltage: 25kV

Category: Underground cable

Installation of Size 3 and 4 plug-in Pfisterer terminations in Como Lake Substation.

Project: Black Spring Ridge Temporary By-pass Construction

Customer: SNC Lavalin

Project Status: 2013

Voltage: 240kV

Category: Transmission

Construct 240kV temporary wood pole bypass on 1005L including vertical tap.

Project: Cope Creek Transmission Lines & Foundations in Cochrane, AB

Customer: SNC Lavalin

Project Status: 2013

Voltage: 138kV

Category: Transmission

Build 138kV Tap Line for Shell Facility, including installation of two 138kV switch structres.

Project: Blackspruce Line Construction in Black Spruce, AB

Customer: SNC Lavalin

Project Status: 2013

Voltage: 240kV

Category: Transmission

138kV Wood Pole Transmission line build through a swamp. All structure sites needed to be matted with access mats to allow access.

Project: Ware Junction 132S Substation Project

Customer: SNC Lavalin

Project Status: Jan. 2014

Voltage: 240kV

Category: Substations

Upgrade Substation Ware Junction 132S, Cassils 324S and West Brooks 28S. Scope outlined covers electricial, grounding, P&C and SCADA cosntruction work in connection with the construction of upgrade 240kV/25kV Ware Junction-132S, Cassils-324S and West Brooks-28S Substations. The scope of work also includes the construction and commissioning of the above listed sites.

Project: EATL-East DC Link Site

Customer: SNC Lavalin

Project Status: 2014

Voltage: 240kV

Category: Transmission

Construct temporary bypasses on six 240kV lines and two permanent bypasses. Construct two QQ towers with Screw pile foundations and 16 Self Supporting Steel poles with caisson foundations.

Project: 1118 Line Work Sunday Creek

Customer: SNC Lavalin

Project Status: 2012

Voltage: 240kV

Category: Transmission

The Sunday Creek 539S Substation Connection Project is the construction of a new 240 kV Single-Circuit Transmission Line (1118L) that connects the new Black Spruce 154S substation to the new Sunday Creek 539S Substation. The length of the new line is approximately 1.9 km.

Project: 240 kV upgrade – debottleneck

Customer: SNC Lavalin

Project Status: ---

Voltage: 240kV

Category: Transmission

Reconductor 9km of Double Circuit 240kV transmission line with 2-bundle 477 ACSR and 1033 ACCR 3M conductor.

Project: Jackfish 698S Transmission Line

Customer: SNC Lavalin

Project Status: 2013

Voltage: 266kV

Category: Transmission

Construct 4km of double Circuit 240kV transmission line, on ten RC22 type lattice towers. String 1590 ACSR and OHSW.

Project: ECTP 240kV Double Circuit 1003L/985L

Customer: SNC Lavalin

Project Status: ---

Voltage: 240kV

Category: Transmission

Construct 21 Self-supporting steel monopoles and double circuit 2-bundle 1033 ACSR. Construct 2.5m - 3m diameter caisson foundations. Construct 240kV Cable Riser Structures.

Project: ECTP Bypass and Lines Construction

Customer: SNC Lavalin

Project Status: ---

Voltage: 138kV / 240kV

Category: Transmission

Construct 240kV tap into Enmax SS65 and Bypass around 5S in Calgary using steel monopoles.

Project: Westwood 422S Substation

Customer: SNC Lavalin

Project Status: 2012

Voltage: 138kV

Category: Substations

Installation of a new AltaLink Modular Design Substation, the key elements for this project include:
- Complete concrete trenches
-Installation of grounding, 25 kV LV power and control cabling.
- Installation and commissioning of SCADA nad associated protection and control modules.
Installation of a new AltaLink Modular Design Substation, the key elements for this project include:
- Bus-works, inerconnection skid with and without voltage transformer and breaker, air switch skid and transformer skid.
-Complete 138kV line in and out termination dead end A-frames with line disconnect switch, surge arrestor and line CVT.

Project: Lines Construction & Foundations (Thompson 140S)

Customer: SNC Lavalin

Project Status: 2012

Voltage: 138kV

Category: Transmission

The Lac La Biche Pump Station Interconnection Project is the construction of a new 138 kV Single-Circuit Transmission Line (788AL) that connected the existing 788L to the new Thompson 140S Substation. The length of the new line is approximately 2.2 km.

Project: Jackfish Line Construction

Customer: SNC Lavalin

Project Status: 2013

Voltage: 266kV

Category: Transmission

Construction of a new 266kV Double Circuit Transmission Line that connects the existing 971L circuit to the new Jackfish 698S Substation. The new double circuit line will serve as an in/out tap to the Jackfish Substation.

Project: Swan River Substation

Customer: ATCO Electric

Project Status: Aug. 2013

Voltage: 144kV

Category: Substations

144kV Expansion of existing 735S Swan River Substation. The scope of work included the following:
- One three phase 144kV current transformer, circuit breaker and manually operated gang disconnect switches; all operated at 72kV.
- One 144/72/25kV 15/20/25 MVA transformer; operated at 72kV.
- Steel structures, stands, Bus-works, cable trays and salvage.
- Installation and termination of high and low voltage cables.
- P&C and SCADA systems and wiring completed; upgraded SCADA to level 4.144kV Expansion of existing 735S Swan River Substation. The scope of work included the following:
- One three phase 144kV current transformer, circuit breaker and manually operated gang disconnect switches; all operated at 72kV.
- One 144/72/25kV 15/20/25 MVA transformer; operated at 72kV.
- Steel structures, stands, Bus-works, cable trays and salvage.
- Installation and termination of high and low voltage cables.
- P&C and SCADA systems and wiring completed; upgraded SCADA to level 4.144kV Expansion of existing 735S Swan River Substation. The scope of work included the following:
- One three phase 144kV current transformer, circuit breaker and manually operated gang disconnect switches; all operated at 72kV.
- One 144/72/25kV 15/20/25 MVA transformer; operated at 72kV.
- Steel structures, stands, Bus-works, cable trays and salvage.
- Installation and termination of high and low voltage cables.
- P&C and SCADA systems and wiring completed; upgraded SCADA to level 4.144kV Expansion of existing 735S Swan River Substation. The scope of work included the following:
- One three phase 144kV current transformer, circuit breaker and manually operated gang disconnect switches; all operated at 72kV.
- One 144/72/25kV 15/20/25 MVA transformer; operated at 72kV.
- Steel structures, stands, Bus-works, cable trays and salvage.
- Installation and termination of high and low voltage cables.
- P&C and SCADA systems and wiring completed; upgraded SCADA to level 4.144kV Expansion of existing 735S Swan River Substation. The scope of work included the following:
- One three phase 144kV current transformer, circuit breaker and manually operated gang disconnect switches; all operated at 72kV.
- One 144/72/25kV 15/20/25 MVA transformer; operated at 72kV.
- Steel structures, stands, Bus-works, cable trays and salvage.
- Installation and termination of high and low voltage cables.
- P&C and SCADA systems and wiring completed; upgraded SCADA to level 4.

Project: Q1W – West 138kV Replacement Structures

Customer: SaskPower

Project Status: 2014

Voltage: 138kV

Category: Energized services

Replacement of 19 structures, 72kV - 230kV, along Q1W-W line.

Project: Transmission Line Construction

Customer: SNC Lavalin

Project Status: 2012

Voltage: 138kV / 240kV

Category: Transmission

Construct 13km of double circuit Steel Pole transmission and foundations. Direct Buried and concrete caisson foundations.

Project: Emergency Repair Work-B2R/B3R 61-66 Repair Ice Damages

Customer: SaskPower

Project Status: 2014

Voltage: 230kV

Category: Transmission

Repair Tower Bases collapsing from ice.

Project: Rowley Substation Construction-S3 Hanna Regional 144kV Substation Bundle

Customer: ATCO Electric

Project Status: 02/06/2012

Voltage: 144kV

Category: Substations

The substation includes three 144 kilovolt (kV) circuit breakers, one 144/25 kV transformer and two 25 kV circuit breakers. This was a turn-key install by Allteck which included complete civil works, steel structures, H/V Equipment, Bus works, SCADA and P&C. Rowley substation is part of the HRTD project for ATCO. Allteck retained its outstanding safety record throughout the build with zero loss time incidents.

Project: Wainwright 51S Transformer Addition

Customer: SNC Lavalin

Project Status: May, 2012

Voltage: 138kV

Category: Substations

Addition of a new 138/25kV, 25/33/42MVA LCT Transformer, two 25kV metal clad switchgear buildings and motorized air switch at the existing Wainwright Substation. Work included site grading, foundations, grounding , electrical, protection, control installation, commission and SCADA.

Project: Supplementary manpower: 2011 Insulator Replacement Project

Customer: Northern British Columbia Client

Project Status: 2011

Voltage: 287kV

Category: Transmission

Insulator replacements on 287kV Transmission line.

Project: 69kV Brule Mine Transmission Line Construction w/ 144kV Under Build

Customer: Western Coal

Project Status: 2011

Voltage: 69kV / 144kV

Category: Transmission

Construction of new 20km 69kV overhead transmission line to feeder Brule Mine.  Work included BC Hydro interconnection.

Project: Refurbishment & Upgrade of Selected City Power 88kV Line Routes

Customer: Edison Jehamo

Project Status: 2012

Voltage: 88kV

Category: Transmission

Upgrade City of Johannesburg's 88 kV transmission system. Allteck, along with their South African partner Edison Jahamo Power, are involved in the energized re-conductoring of multiple 88kV circuits using ACCC high temperature conductor. This work is completed using liveline barehand techniques. City Power identifies the circuits to be upgraded and Allteck and EJP embark on a program to change the existing conductors while not losing any circuit capacity on the existing circuits. This is the first work of this kind to be performed outside of North America and is a service unique to Quanta Services' operating units.

Project: Cross Arm Replacements and Primary Repairs

Customer: BC Hydro

Project Status: 26/01/2015

Voltage: 25kV

Category: Distribution

Cross Arm Distribution Maintenance

Project: Overhead Pole Replacements/Removals- Various Locations, BC

Customer: BC Hydro

Project Status: 09/09/2014

Voltage: 25kV

Category: Distribution

Overhead Pole Replacements/Removals

Project: Feeder cable installation

Customer: BC Hydro

Project Status: 27/06/2014

Voltage: 25kV

Category: Underground cable

Feeder Cable Installation, including pulling, splicing and VLF testing.

Project: Feeder cable installation

Customer: BC Hydro

Project Status: 14/03/2014

Voltage: 25kV

Category: Underground cable

Switch Replacement, Replace UC to Vista with new 3(g13) Feeder cable splicing and install.

Project: Butterfly Templates & 4 Circuits in Delta, BC

Customer: BC Hydro

Project Status: 02/02/2014

Voltage: 25kV

Category: Underground cable

Vista Feeder cable & primary cable installation. OH removals.

Project: 2,602 Pole Replacements, Vancouver area

Customer: BC Hydro

Project Status: 2014

Voltage: 25kV

Category: Distribution

2,602 distribution pole replacements in the Vancouver area.

Project: 1,125 Pole Replacements

Customer: BC Hydro

Project Status: 2013

Voltage: 25kV

Category: Distribution

1,125 distribution pole replacements in multiple locations across Vancouver & the Tri-cities, BC.

Project: 1000 pole replacements – Phase 2 RFT 1376

Customer: BC Hydro

Project Status: 2013

Voltage: 25kV

Category: Distribution

100 distribution pole replacements in multiple locations across BC.

Project: Distribution Manholes & Asbestos

Customer: BC Hydro

Project Status: 15/02/2014

Voltage: 25kV

Category: Underground cable

Inspection and tagging of 3000 Distribution manholes for asbestos.

Project: Concrete & Wood Pole Replacements & Reconductoring

Customer: BC Hydro

Project Status: 30/09/2012

Voltage: 25kV

Category: Distribution

Richmond 3 phase conversion.

Project: 389 Pre-Design Pole Replacements

Customer: BC Hydro

Project Status: 2012

Voltage: 25kV

Category: Distribution

Pre-design pole replacement pilot project with AMEC.

Project: Insulator Replacement & Arc Horn Installation Program

Customer: BC Hydro

Project Status: 01/03/2013

Voltage: 500kV

Category: Energized services

500kV energized insulator replacement & arc horn installation.

Project: Spacer Damper Replacement Transmission Project

Customer: BC Hydro

Project Status: 31/03/2012

Voltage: 500kV

Category: Energized services

Replacement of spacer dampers on circuit 5L12 structures spanning approximately 200 miles.

Project: 1400 Pole Replacements

Customer: BC Hydro

Project Status: 28/02/2012

Voltage: 25kV

Category: Distribution

Renewal of approximately 1400 distribution poles in various locations across the Lower Mainland of British Columbia.

Project: Inspection/Maintenance of cable circuits in manholes

Customer: BC Hydro

Project Status: 21/03/2012

Voltage: 25kV

Category: Underground cable

Distribution manhole inspections.

Project: OPGW Installation

Customer: Sharyland Utilities

Project Status: In progress

Voltage: 138kV

Category: Energized services

Allteck has supplied 2 Barehand Linemen to work alongside North Houston Pole Line on replacing static line with OPGW above an energized 138kV line.

Project: Energized Transmission Reconductor Project

Customer: American Electric Power

Project Status: 2015

Voltage: 345kV

Category: Energized services

Allteck has supplied 6-10 Barehand Linemen to work along side North Houston Pole Line on their energized 345kV reconductor project using barehand methods to install new 795ACCC fiber core conductor and vacuum switches to transfer load.

Project: 72L Rehab 2015

Customer: FortisBC

Project Status: 2015

Voltage: 230kV

Category: Transmission

Allteck completed the rehabilitation of the 72 line in Okanagan, B.C. the work consisted mostly of structure replacements of 230kV H-Frame wood pole structures.

Project: 11 Line Rehabilitation Services

Customer: FortisBC

Project Status: 2015

Voltage: 161kV

Category: Transmission

11LW is a 161kV line which connects the Fortis BC Kettle Valley station and the Grand Forks Terminal station. Allteck performed structure replacements as well as repairs to the 35km of line.

Project: RFQ for 750 AMI Services, Kelowna, BC

Customer: FortisBC

Project Status: 2015

Voltage: 25kV

Category: Distribution

Rehabilitation of distribution line in the areas of Oliver, BC, Greenwood BC and Rock Creek BC.

Project: 6-26 Line Rehabilitation Services

Customer: FortisBC

Project Status: 2014

Category: Transmission

Allteck replaced and repaired structures in various locations encountering river crossings. Work included live line work and other rehabilitation

Project: 20 Line Rehabilitation Services

Customer: FortisBC

Project Status: 2014

Voltage: 69kV

Category: Transmission

Allteck was responsible for the rehabilitation of 44km of single pole transmission line around Salmo BC.

Project: Nisga Fibre Southern Terminus Stringing

Customer: Midgard Consulting

Project Status: 2015

Category: Distribution

This project involved the installationof 48 strand ADSS Fiber Optic Cable form New Romo to Terrace BC to complete the southern terminus segment of the Nisga'Fiber Optic Project.

Project: 25kV Single Line Engineer & Install at Man Camp

Customer: Encana

Project Status: 2015

Voltage: 25kV

Category: Distribution

Allteck performed maintenance on Encana annual shut down.

Project: Kluskus I.R.#1 Power Line Tender

Customer: RKTG / Telus

Project Status: 2015

Voltage: 14.4kV

Category: Distribution

Allteck completed the construction of a new overhead 14.4kV single phase wood pole power line to service Telus new wire line site. This line spanned 2.5km in Quesnel BC.

Project: Kitimat, BC Insulator Replacements

Customer: Northern BC Client

Project Status: Ongoing

Voltage: 287kV

Category: Transmission

Replacement of insulators from Kemano to Kitimat on 287kV line, a distance of 83km across rugged mountainous terrain via helicpoter access. This line consisted of both Aluminum and Steel towers.

Project: O&M High Voltage Municipality Substation

Customer: City of New Westminster

Project Status: 2015

Voltage: 60kV

Category: Substations

Allteck to perform inspection, testing, adjustments, maintenance and repair of electrical equipment located inside the substation. Maintaining the substation power transformers, Circuit breakers and much more.

Project: 138 & 230kV Retermination of transmission line SNC-Lavalin

Customer: Valard

Project Status: 2015

Voltage: 230kV

Category: Transmission

Modification of existing line from Chetwynd sub to Bear Mountain sub had to be reterminated into a new circuit from Chetwynd to Sundance.

Project: Aberdeen to Beatty, SK Wind Storm Emergency Response

Customer: SaskPower

Project Status: 2015

Voltage: 230kV

Category: Transmission

Strong winds caused substantial damage to 230kV infrastructure and double circuit grid line connecting Aberdeen and Beatty switching stations. Installation and repair of new shield wire wings was required in addition to large lattice tower repairs.

Project: K+S and Enbridge Bethune New Transmission Line Project

Customer: SaskPower

Project Status: 2015

Voltage: 230kV

Category: Transmission

Construction of 187 new 230kV steel poles to supply power from Pasqua substation (20km outside of Moose Jaw Saskatchewan) to a new K+S potash mine as well as a TAP of 16 structures to the Bethune Substation.

Project: Transmission Tower Replacement project

Customer: Northern British Columbia client

Project Status: Ongoing

Voltage: 230kV

Category: Transmission

Allteck was required to raise the wire height to accommodate Shell Canada transporting new LNG modules to build an LNG terminal. The scope of the work included replacing a double circuit 287kV lattice tower with four 220’ single circuit steel H-Frame towers in order to raise the conductors well above the road surface to allow for large load transportation from the dock facility.

Project: Construction of new 144kV Double Circuit Steel Pole Transmission line from High Prairie substation

Customer: ATCO Electric

Project Status: 2014

Voltage: 144kV

Category: Transmission

Construction of 12.8km of new 144kV double circiut transmission line from the High Prairie substation to the Traingle substation, crossing two railways, one 72kV crossing, highway crossing and multiple road/pipeline and water crossings.

Project: Construction of new facility and refurb of Quintette Coal Mine

Customer: Teck Coal/AMEC

Project Status: 2013

Voltage: 69kV

Category: Transmission

Completed the construction of new facilities as well as refurbishment of some of the existing buildings and equipment spanning 10km of the Quintette Coal Mine 20km south of Tumbler Ridge, BC.

Project: Humboldt, SK Line Remediation

Customer: SaskPower

Project Status: 2014

Voltage: 72kV

Category: Energized services

Replacement, repair and inspection of 57 transmission structures of overhead line energized at 72kV over three separate lines in Wolverine, Cudworth and Watson, Saskatchewan.

Project: Roundhill 240kV Double Circuit Transmission Line

Customer: SNC Lavalin

Project Status: 2012

Voltage: 230kV

Category: Transmission

Allteck was responsible for the construction of the new 10.7 km roundhill 240kV double circuit transmission line from ATCO tap point to the Roundhill substation.

Project: Hartley Bay, BC Hydro Pole Replacement Project

Customer: BC Hydro

Project Status: 2015

Voltage: 25kV

Category: Distribution

Replace 5 three phase poles and 1 single phase pole.

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: Ongoing

Voltage: 138kV

Category: Transmission

Climbing inspections, hardware tightening starting at Sechelt substation to Gibsons substation on 138kV structures.

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: Ongoing

Voltage: 230kV

Category: Transmission

Climbing inspections and hardware tightening starting at Malaspina substation to Sechelt substation on 230 kV structures.

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: Ongoing

Voltage: 230kV

Category: Transmission

Climbing inspections and hardware tightening starting at the Malaspina substation to Howe Sound substation on 230 kV structures.

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: Ongoing

Voltage: 500kV

Category: Transmission

Climbing inspections and hardware tightening starting at Mackenzie substation to Morphee substation on 500kV structures.

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: Ongoing

Voltage: 138kV

Category: Transmission

Climbing inspections and hardware tightening starting at Valleyview substation to Salmon Arm substation on 138kV structures

Project: Multi-Location Climbing inspections, Overhead and Underground Transmission

Customer: BC Hydro

Project Status: 2015

Voltage: 138kV

Category: Transmission

Climbing Inspections, Overhead and Underground Transmission starting at John Hart substation to Elk Falls substation on 138kV structures

Project: Replacement of 50 138kV Wood Poles, Fort St John, BC

Customer: BC Hydro

Project Status: 2015

Voltage: 138kV

Category: Transmission

Replacement of approx 50 wood pole transmission structures which runs between FM Shrum and Fort St. John, substations also approx 40 locations that required the replacement of hardware and cross arms

Project: Lower Mainland Restoration Rating

Customer: BC Hydro

Project Status: 2012

Voltage: 69kV

Category: Transmission

Replace/repair 11 damaged structures on 60L99 rock excavation, drilling, blasting from Cypress substation to Glenmore susbstation

Project: Lower Mainland Restoration Rating

Customer: BC Hydro

Project Status: 2012

Voltage: 69kV

Category: Transmission

Replace/repair 17 damaged structures on 60L65 from John Lawson substation to Cypress substation

Project: Lower Mainland Restoration Rating

Customer: BC Hydro

Project Status: 2012

Voltage: 69kV

Category: Transmission

Replace/repair 12 damaged structures on 60L64 from Capilano substation to Walters substation

Project: 3 Phase Reconductoring & Pole Replacement

Customer: BC Hydro

Project Status: 2010

Voltage: 25kV

Category: Distribution

3 Phase Reconductoring and Pole Replacement from Kent substation travelling 7km in Harrison Hot Springs and Chilliwack BC

Project: Endako Mine – Transmission Line Construction

Customer: BCTC

Project Status: 2010

Voltage: 60kV

Category: Transmission

Contruction of a 60kV Line connecting the Hydro system to the Endako mine.

Project: 138kV Underground Cable Installation

Customer: Ganotec

Project Status: 2015

Category: Underground cable

Project: Emergency Response to multiple tower damage on A1B/A2B Transmission Line

Customer: SaskPower

Project Status: Complete

Voltage: 230Kv Double Circuit

Category: Emergency restoration

In December of 2014, heavy ice loading caused broken Shield Wire and damaged the OHSW tower wings requiring wing replacements and replacement of 7.5km of double shield wire. SaskPower called Allteck during the Christmas Holiday for emergency repairs to the 230kV double circuit steel towers damaged due to ice.

Project: Encana substation site construction and installation

Customer: Encana Natural Gas

Project Status: Completed

Voltage: 138Kv

Category: Substations

Allteck was engaged by Encana to provide services as prime contractor for the construction of the substation that services the Saturn Sister Phase 1 Compressor Station located 25 km northwest of Dawson Creek, BC.

Project: B.C. Hydro Energized Spacer Replacement – Smithers to Vancouver Island

Customer: BC Hydro

Project Status: In progress

Voltage: 500kV

Category: Energized services

BC Hydro required the replacement of spacers spanning from Smithers B.C. all the way to Vancouver Island. The multi-year project began in 2012 and involved 46,000 spacers on 13 circuits with a total length of about 1200km with a combination of 500kV and 230kV transmission lines.

Project: Langdon & Bennett substation project – West Alberta Transmission Line

Customer: SNC-Lavalin

Project Status: Complete

Voltage: 240Kv & 500Kv

Category: Substations

The co-located Langdon 240kV and the Bennett 500kV substations are part of AltaLink’s Western Alberta Transmission Line Project (WATL).

Project: Direct Bury Cable Installation, Janet Substation Calgary

Customer: VISCAS CORP

Project Status: Complete

Voltage: 240kV

Category: Underground cable / Substations

VISCAS required the installation of and termination support for two 240kV cable circuits for a larger project at SNC-Lavalin’s Janet Substation. Allteck was responsible for cable installation and assisting the client with termination and testing. The project scope included civil work for trenching and backfilling, scaffold installation and removal, low voltage testing, and high voltage testing support.

Project: High Pressure Pipe Type 69kV Cable Termination Repair

Customer: Canfor Pulp Mill

Project Status: 2015

Category: Underground cable

Canfor Pulp Mill hired Allteck to replace a leaking high-pressure Canada Wire type termination. This termination was built in 1964 and was subject to severe corrosion issues which resulted in a cable oil leak. Allteck’s high-voltage installation crew carried out the replacement of the termination and utilized specialized oil purification degassing equipment to purify the existing cable oil.

Project: Kettle River Line Construction for the Enbridge Transmission Development Project

Customer: Atco Electric

Project Status: In progress

Voltage: 240kV

Category: Transmission

Kettle River was a new ‘in-out’, double circuit line connecting a newly constructed substation to the grid. 240kV Construction which was bundled 477 Hawk conductor. The project included installation of OHSW (overhead shield wire), OPGW (optical ground wire) and salvage of conductor wire. Allteck constructed 9 towers and several wood structures with a circuit length of about 4.5 km.

Project: B.C. Arcing Horns Replacement Project

Customer: BC Hydro

Project Status: Ongoing

Voltage: 500kV

Category: Energized services

This project consists of the replacement of insulators and installing arcing horns on various 500kv circuits throughout BC.

Project: Northern British Columbia – Transmission Tower Replacement

Customer: Northern British Columbia

Project Status: Complete

Voltage: 287kV

Category: Transmission